ZESTAW STARTOWY LOGO! 12/24V + LOGO! TD, ZAWIERA: LOGO! 12/24RCO, WYŚWIETLACZ TEKSTOWY LOGO! TD, KABEL USB, OPROGRAMOWANIE LOGO! SOFT COMFORT V7, DOKUMENTACJĘ, ŚRUBOKRĘT; WERSJA ANG./NIEM....
STYK POM. POPRZECZNY, 1NO+1NC, ZACISKI ŚRUBOWE, DO WYŁĄCZNIKÓW W WIELKOŚCI S00 DO S2
SIMATIC S7-1200, CPU 1212C DC/DC/PRZEKAŹNIK, 8 WEJŚĆ BINARNYCH (24V DC) / 6 WYJŚĆ BINARNYCH (PRZEKAŹNIK/2A) / 2 WEJŚCIA ANALOGOWE (0 - 10V DC), ZASILANIE: 24V DC, PAMIĘĆ PROGRAMU/DANYCH: 50 KB...
LOGO! CSM12/24 COMPACT SWITCH MODULE CONNECTION OF A LOGO! (. ..0BA7/...0BA8) AND UP TO 3 FURTHER NODES TO IND. ETHERNET WITH 10/100 MBIT/S UNMANAGED SWITCH, 4 RJ45 PORTS, 1X FRONT PORT FOR DIAGNOSTICS DC 12/24V POWER SUPPLY LED DIAGNOSTICS, LOGO! SETUP....
CIM COMMUNICATION INTERFACE MODULE FOR LOGO! 8 MODBUS RTU INTERFACE (RS232/485) 4-PORT SWITCH; WITHOUT 4G/LTE/GPS ENGINE; WITHOUT ANTENNAS; WEB CONFIGURATOR...
LOGO! AM4 AI AQ EXPANSION MODULE PS/: 24 V DC, 2 AI, 0-10 V OR 0/4-20 MA 2 AO, 0-10 V OR 0/4-20 MA FOR LOGO! 9
LOGO! DM8 12/24R EXPANSION MODULE, POWER SUPPLY / I/O: 12, 24 V/12 V/24 V/RELAY, 2 MW, 4 DI/4 DO FOR LOGO! 9
LOGO! DM8 230R EXPANSION MODULE, POWER SUPPLY / I/O: 230 V/230 V/RELAY, 2 MW, 4 DI/4 DO FOR LOGO! 9
LOGO! 12/24RCEO, LOGIC MODULE, POWER SUPPLY / I/O: 12/24 V DC/RELAY, 8 DI (4 AI)/4 DO, WITHOUT DISPLAY, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL LOGO! BASIC UNITS...
LOGO! 24RCEO (AC), LOGIC MODULE, POWER SUPPLY / I/O: DC 24 V DC/24 V AC/RELAY, 8 DI/4 DO, WITHOUT DISPLAY, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL LOGO! BASIC UNITS...
LOGO! 230RCEO, LOGIC MODULE, POWER SUPPLY / I/O: 115 V/230 V/RELAY, 8 DI/4 DO, WITHOUT DISPLAY, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL LOGO! 9.0 BASIC UNIT...
LOGO! 24CEO, LOGIC MODULE, WITHOUT DISPLAY, POWER SUPPLY / I/O: 24 V/24 V/24 V TRANS., 8 DI (4 AI)/4 DO, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE, CLOUD CONNECTION, MQTT IN ALL LOGO! BASIC UNITS...
LOGO! 12/24RCE, LOGIC MODULE, DISPLAY POWER SUPPLY / I/O: 12/ 24 V DC/RELAY, 8 DI (4 AI)/4 DO, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD, FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL LOGO! BASIC UNITS TOUCH DISPLAY...
LOGO! 24RCE, LOGIC MODULE,DISPLAY POWER SUPPLY / I/O: 24 V AC/DC 24 V/RELAY, 8 DI/4 DO, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL BASIC UNITS TOUCH DISPLAY...
LOGO! 230RCE,LOGIC MODULE, DISPLAY POWER SUPPLY / I/O: 115 V/230 V/RELAY, 8 DI/4 DO, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET, INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL LOGO! BASIC UNITS TOUCH DISPLAY...
LOGO! 24CE, LOGIC MODULE, DISPLAY POWER SUPPLY / I/O: 24 V/24 V/24 V TRANS., 8 DI (4 AI)/4 DO, MEMORY 800 BLOCKS, MODULARLY EXPANDABLE, ETHERNET INTEGRATED WEB SERVER, DATA LOG, USER-DEFINED WEB PAGES, STANDARD MICROSD CARD FOR LOGO! SOFT COMFORT V9.0 OR HIGHER, OLDER PROJECTS EXECUTABLE CLOUD CONNECTION, MQTT IN ALL BASIC UNITS TOUCH DISPLAY...
MODUŁ KOMUNIKACYJNY LOGO! CMK2000 DO INTEGROWANIA LOGO! 8 "W SYSTEMY AUTOMATYKI BUDYNKOWEJ KNX;" POŁĄCZENIE 24 V DC 0.04A 1 PORT RJ45 DLA 50 OBIEKTÓW KOMUNIKACYJNYCH ETHERNET SYNCHRONIZACJA CZASU KONFIGURACJA/DIAGNOSTYKA POPRZEZ INTERFEJS WEB...
SIMATIC S7-300, ZASILACZ PS 307, NAPIĘCIE WEJŚCIA: 120/230V AC, NAPIĘCIE WYJŚCIA: 24V DC / 5A
SIMATIC MEMORY CARD, KARTA PAMIĘCI FLASH DLA STEROWNIKÓW S7-1200/S7-1500, 3.3V, 4 MB
SIMATIC S7, KARTA PAMIĘCI MMC (MICRO MEMORY CARD) DLA STEROWNIKÓW SIMATIC S7-300/C7/ET 200, 3.3V, PAMIĘĆ TYPU FLASH, 64 KB Kolejną wersją tego produktu jest: 6ES7953-8LF31-0AA0 ...
SIMATIC S7, KARTA PAMIĘCI MMC (MICRO MEMORY CARD) DLA STEROWNIKÓW SIMATIC S7-300/C7/ET 200, 3.3V, PAMIĘĆ TYPU FLASH, 4 MB...
SIMATIC S7, KARTA PAMIĘCI MMC (MICRO MEMORY CARD) DLA STEROWNIKÓW SIMATIC S7-300/C7/ET 200, 3.3V, PAMIĘĆ TYPU FLASH, 128 KB Kolejną wersją tego produktu jest: 6ES7953-8LG31-0AA0 ...
SIMATIC MEMORY CARD, KARTA PAMIĘCI FLASH DLA STEROWNIKÓW S7-1200/S7-1500, 3.3V, 24 MB
SIMATIC MEMORY CARD, KARTA PAMIĘCI FLASH DLA STEROWNIKÓW S7-1200/S7-1500, 3.3V, 12 MB
SIMATIC S7, KARTA PAMIĘCI MMC (MICRO MEMORY CARD) DLA STEROWNIKÓW SIMATIC S7-300/C7/ET 200, 3.3V, PAMIĘĆ TYPU FLASH, 512 KB...
SIMATIC S7, KARTA PAMIĘCI MMC (MICRO MEMORY CARD) DLA STEROWNIKÓW SIMATIC S7-300/C7/ET 200, 3.3V, PAMIĘĆ TYPU FLASH, 2 MB...